Review Article

Published: Oct 29, 2026 | DOI: 10.24911/amem.15-3124

Diagnostic performance of ultrasound elastography combined with ACR TI-RADS for thyroid nodule assessment: a systematic review and meta-analysis


Authors: Joud Alghamdi , Thana Algarni , Rama Alawi , Malath Alkathiri , Arwa Alariany , Basmah Sherbini , Hams Aljadani , Taif Alenezi , Dareen Bajamaan , Raghad Filimban , Sara Aljahdali , Amr M. Daous


Abstract

Introduction: Thyroid nodules are common, and most are benign. Risk stratification is important for detection of malignancy and avoidance of unnecessary fine-needle aspiration (FNA). The American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) provides standardized ultrasound-based assessment, and elastography has been suggested as an adjunct. This study aimed to evaluate the diagnostic performance of elastography combined with ACR TI-RADS and its impact on biopsy recommendation.
 
Methods: This systematic review and meta-analysis followed PRISMA guidelines and registered a priori in PROSPERO. Studies assessing the combined method of elastography plus ACR TI-RADS in correlation with histopathology and/or fine-needle aspiration cytology were included. Pooled sensitivity and specificity were calculated through a bivariate random-effect model, and diagnostic performance was assessed by hierarchical summary receiver operating characteristic analysis.
 
Results: Fifteen studies were selected. The pooled sensitivity, specificity, and area under the curve (AUC) of ACR TI-RADS alone were 84.1%, 76.0%, and 0.874, respectively. Adding elastography raised sensitivity to 90.5% but reduced specificity to 18.8%, with a lower AUC of 0.711. The pooled estimate indicated 41.1% of biopsies could be potentially avoided, but the estimate was compromised by substantial heterogeneity (I2=98.4%) and limited generalizability. The combined false-negative rate was 3.0% with significant heterogeneity.
 
Conclusions: In our study, ACR TI-RADS alone showed more balanced performance than the combined systems. Adding elastography increased sensitivity but decreased specificity and overall diagnostic accuracy. Evidence on biopsy reduction is uncertain due to high heterogeneity. These results do not support routine elastography for reducing FNA, but selective adjunctive use warrants further prospective studies.

Keywords: Thyroid nodules, ultrasound elastography, ACR TI-RADS, fine-needle aspiration, diagnostic accuracy.



Pubmed Style

Joud Alghamdi, Thana Algarni, Rama Alawi, Malath Alkathiri, Arwa Alariany, Basmah Sherbini, Hams Aljadani, Taif Alenezi, Dareen Bajamaan, Raghad Filimban, Sara Aljahdali, Amr M. Daous. Diagnostic performance of ultrasound elastography combined with ACR TI-RADS for thyroid nodule assessment: a systematic review and meta-analysis. AMEM. 2026; 29 (October 2026): -. doi:10.24911/amem.15-3124

Publication History

Received: August 25, 2026

Revised: September 03, 2026

Accepted: October 03, 2026

Published: October 29, 2026


Authors

Joud Alghamdi

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Thana Algarni

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Rama Alawi

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Malath Alkathiri

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Arwa Alariany

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Basmah Sherbini

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Hams Aljadani

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Taif Alenezi

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Dareen Bajamaan

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Raghad Filimban

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Sara Aljahdali

College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.

Amr M. Daous

Department of Radiology, College of Medicine, University of Jeddah, Jeddah, Saudi Arabia.